CREEP AND CREEP-RUPTURE TESTING  (ASTM E139)

JML has approximately 400 creep and creep-rupture test frames with capacities ranging from direct load to 30,000 lbs. Testing is conducted from room temperature to 2200 F. in air. Testing is performed using dual extensometer measuring systems for superior definition at low strain during primary creep. Test report includes Rupture Time, % Elongation, % RA, Final Creep Reading and Creep Curve and Data in hard copy and electronic format. Additional data analysis is also available upon request.